Signalling Connection Control Part (SCCP) Protocol

The Signalling Connection Control Part (SCCP) is a network layer protocol that provides extended routingflow control, segmentation,connection-orientation, and error correction facilities in Signaling System 7 telecommunications networks. SCCP relies on the services of MTP for basic routing and error detection.

Routing facilities beyond MTP

Although MTP provides routing capabilities based upon the Point Code, SCCP allows routing using a Point Code and Subsystem number or a Global Title.

A Point Code is used to address a particular node on the network, whereas a Subsystem number addresses a specific application available on that node. SCCP employs a process called Global Title Translation to determine Point Codes from Global Titles so as to instruct MTP on where to route messages.

SCCP messages contain parameters which describe the type of addressing used, and how the message should be routed:

  • Address Indicator
    • Routing indicator
      • Route on Global Title
      • Route on Point Code/Subsystem Number
    • Global title indicator
      • No Global Title
      • Global Title includes Translation Type (TT), Numbering Plan Indicator (NPI) and Type of Number (TON)
      • Global Title includes Translation Type only
    • Subsystem indicator
      • Subsystem Number present
      • Subsystem Number not present
    • Point Code indicator
      • Point Code present
      • Point Code not present
  • Global Title
    • Address Indicator Coding
    • Address Indicator coded as national (the Address Indicator is treated as international if not specified)

Protocol classes

SCCP provides 5 classes of protocol to its applications:

  • Class 0: Basic connectionless.
  • Class 1: Sequenced connectionless.
  • Class 2: Basic connection-oriented.
  • Class 3: Flow control connection oriented.
  • Class 4: Error recovery and flow control connection oriented.

The connectionless protocol classes provide the capabilities needed to transfer one Network Service Data Unit (NSDU) in the “data” field of an XUDT, LUDT or UDT message. When one connectionless message is not sufficient to convey the user data contained in one NSDU, a segmenting/reassembly function for protocol classes 0 and 1 is provided. In this case, the SCCP at the originating node or in a relay node provides segmentation of the information into multiple segments prior to transfer in the “data” field of XUDT (or as a network option LUDT) messages. At the destination node, the NSDU is reassembled.

The connection-oriented protocol classes (protocol classes 2 and 3) provide the means to set up signalling connections in order to exchange a number of related NSDUs. The connection-oriented protocol classes also provide a segmenting and reassembling capability. If an NSDU is longer than 255 octets, it is split into multiple segments at the originating node, prior to transfer in the “data” field of DT messages. Each segment is less than or equal to 255 octets. At the destination node, the NSDU is reassembled.[3]

Class 0: Basic connectionless

The SCCP Class 0 protocol class is the most basic of the SCCP protocol classes. Network Service Data Units passed by higher layers to the SCCP in the originating node are delivered by the SCCP to higher layers in the destination node. They are transferred independently of each other. Therefore, they may be delivered to the SCCP user out-of-sequence. Thus, this protocol class corresponds to a pure connectionless network service. As a connectionless protocol, no network connection is established between the sender and the receiver.

Class 1: Sequenced connectionless

SCCP Class 1 builds on the capabilities of Class 0, with the addition of a sequence control parameter in the NSDU which allows the SCCP User to instruct the SCCP that a given stream of messages should be delivered in sequence. Therefore, Protocol Class 1 corresponds to an enhanced connectionless protocol with assurances of in-sequence delivery.

Class 2: Basic connection-oriented

SCCP Class 2 provides the facilities of Class 1, but also allows for an entity to establish a two-way dialog with another entity using SCCP.

Class 3: Flow control connection oriented

Class 3 service builds upon Class 2, but also allows for expedited (urgent) messages to be sent and received, and for errors in sequencing (segment re-assembly) to be detected and for SCCP to restart a connection should this occur.

Reference : http://en.wikipedia.org/wiki/Signalling_Connection_Control_Part

Advertisements

Leave a Reply

Please log in using one of these methods to post your comment:

WordPress.com Logo

You are commenting using your WordPress.com account. Log Out / Change )